DYNA-TITE TESTING & WARNINGS

EFFECTS OF HANGING AT ANGLES

Cable locks can be used to suspend objects safely at angles of up to 60 degrees from the vertical. However, suspension at angles does reduce the safe working load per the table below.

Size Vertical 15° 30° 45° 60°
WC8-25 1,100 lbs 1,060 lbs 950 lbs 775 lbs 550 lbs
WC6-23 640 lbs 625 lbs 559 lbs 455 lbs 325 lbs
WC4-18 250 lbs 240 lbs 215 lbs 175 lbs 125 lbs
WC3-12 150 lbs 144 lbs 129 lbs 105 lbs 75 lbs
WC2-6 75 lbs 72 lbs 64.5 lbs 52.5 lbs 37.5 lbs
Load 100% 96% 86% 70% 50%

TESTING

All Dyna-Tites have been independently tested to five times their allowable working load by one or more of the following independent laboratories:

  • RADCO Inc, Long Beach CA
  • SMACNA testing and Research Institute
  • New York Testing Laboratories

Testing Labs Logo

WARNINGS

As a matter of sound engineering practice, the Dyna-Tite assembly must be located no closer than 12 inches to the suspension point. In the case of round duct, where the wire rope encircles the duct, the Dyna-Tite must be located the distance of one diameter from the duct wall. Adherence to these minimum clearances will distribute the load the most efficiently among all duct hanging components.

>> FOR STATIC LOAD APPLICATIONS ONLY <<

  • ALWAYS CONFIRM ENGAGEMENT OF CABLE LOCK ON WIRE BEFORE APPLYING THE LOAD: By pushing the adjustment pin in the opposite direction of the arrows on the cable lock and then pulling the cable also in the opposite direction of the arrows on the cable lock.
  • PULL ADJUSTMENT PIN BACK AND PASS WIRE ROPE THROUGH DYNA-TITE CABLE LOCK: Failure to pull adjustment pin first may cause damage to serrated teeth and reduce holding capacity.
  • TO ENSURE HANGING SYSTEM INTEGRITY AND SAFETY: Use only Duro Dyne wire rope.
  • WORKING LOAD LIMIT (WLL) MUST FALL WITHIN THE STATED WORKING LOAD RANGE OF THE CABLE LOCK: Each product is load rated and incorporates a minimum safety factor of 5:1. This WLL takes into account the specification criteria of the Dyna-Tite Cable Lock and the wire rope.
  • Do not use on coated wire rope: It is important to maintain the metal to metal contact between the locking pawls in the Dyna-Tite and the wire rope.
  • Do not apply paint or other coating: to any part of the assembly as these may impair the free movement of the locking pawls inside the Dyna-Tite Cable Lock.
  • Do not apply lubricant: to any part of the assembly as this will alter the surface nature of the wire rope and attract dirt and debris.
  • Do not use for lifting: (Under Hook slings) This product is designed for static load applications only.
  • Keep the product clean and free from dirt: Any dirt should be removed from the product prior to assembly.
  • Inspect periodically: Upon inspection, discard and replace if worn, distorted, or damaged.
  • Remove damaged wire ends: Using a designated pair of wire rope cutters prior to inserting into the Dyna-Tite Cable Lock.
  • When installing Duro Dyne Dyna-Tite cable attachments: to buildings or equipment careful consideration must be made to the attachment method and the material being attached to. It is the responsibility of the installer for the proper selection, installation and appropriateness of the attachment to the job specifications and any codes. Duro Dyne can give general guidance, but any questions regarding this should ultimately be directed to the project engineer of the job.
  • For dry locations only
  • Do not use in chlorinated atmospheres such as pools and natatorium
  • Gymnasium installs must use the locking cable locks only
WordPress Appliance - Powered by TurnKey Linux